Model No. PFBD15
Prime Power             kW/kVA 12/15
Standby Power         kW/kVA 13/16
Engine Model F2L912D
Alternator Model EG164DQ
Dimensions               mm 1300*700*1100
Weight                        kg 560

Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T282097 (eqv ISO8528): A 10% overload capability is available for a period of 1 hour within 12 hour period of operation.

Standby Power (ESP): The Standby Power is applicable for supplying emergency power for the duration of autility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.

Ambient reference conditions: altitude 1000m, air pressure 100kpar, relativehumidity40%, ambient temperature 40.

Standard Specifications

General Features

  • 400/230V, 50 Hz at 1500rpm, 3-Phase, 0.8pf
  • Deutz engine with Engga alternator
  • Electric start, electric speed governor
  • 24V Charge alternator
  • Dry type air filter, fuel filter, oil filter
  • Single bearing alternator
  • Class “H” insulation, IP 22 protection grade
  • Main line circuit breaker
  • Manual control panel
  • Optional digital control panel
  • Battery and connect wires
  • Flexible pipe and silencer
  • User manual and documents
  • Full function test before dispatch

Electric Data

Voltage 400/230V (1)
Frequency   50Hz (2)
Connecting type 3 phase 4 wires
Power factor 0.8 (lagging)
Exciter type  Single bearing brushless ,self exciting
Insulation class H/H
Protection grade IP21/23
Voltage control AVR
Voltage regulation ≤2.5% (stead state)
≤(20+25)% (transient state)
Volt. stable time ≤1.5S
Voltage waving ≤1%
Frequency regulation ≤5% (stead state)
≤+10)% (transient state)
Frequency recover time ≤5S
Frequency waving ≤1%

Comments
(1) Voltage 220/110V, 380/230V, 415/240V, 440/254 are available.
(2) Above data are based on 50 Hz products. For 60 Hz product, please contact us.

Standards & Certifications

ISO8528, GB/T2820, ISO3046, BS4999, BS5000 PT99
AS1359, IEC34
UTE5100, VDE0530
ISO9001:2000, ISO14001

Engine Specifications

Manufacturer/brand: Deutz

Main advantages

  • Protection against diverse weather and ambient conditions
  • Highly functional and modern industrial design ensure economical and lowconsumption
  • The shaping assists the easy and safe handling
  • All control and monitoring functions as well as the connectors are centralised for easy accessibility
  • Cylinder cap with high strength nodular iron casting
  • Connecting rods with drop forged high carbon alloy steel
  • Crankshaft with high alloy steel forging and bolt-on counterweights
  • Dry element air filter with visual restriction indicators and turbocharged
  • Fuel system ensures the cleanness of fuel in injection pump and increase the lifetime of injection pump
  • Turbocharged diesel engines keep the engine working at high intensity low vibration and low noise
Model No: F2L912D
Engine Type: 2L, 4 cycle
Max. Engine Power kW 16
Aspirate Turbocharged,intercooled
Governor Type Electronic governor
Cooling Method Air cooled
Number of cylinders 2
Bore x stroke:     mm 100 x 120
Displacement: L 1.88
Fuel consumption  
100%G/kwh 3.4
Lub. Oil Capacity: L 8.0
Exhaust Temp: Celsius 500

 

AC Alternator Specifications

  • 2/3 pitch design avoids excessive neutral currents and also ensures very low waveform distortion
  • Brushless alternator with brushless pilot exciter for excellent load response
  • AVR or DVR Self regulation ensure the steady voltag eoutput which benefit your equipment
  • Easy Paralleling with mains or other generators, 2/3 pitch stator windings avoid excessive neutral currents
  • Alternators meet the requirement of NEMA, IEC, IEEE, CSA, BS which ensure the high quality performance
  • Self driven cooling fan ensure the working temperature
Technical Data
Manufacturer Engga
Model No EG164DQ
Voltage 400/230V
Frequency 50Hz
Stator 2/3pitch
Connecting type 3 phase 4 wires
Power factor 0.8 (lagging)
Exciter type Brushless,selfexcited
Insulation class H/H
  Engga AC Alternator Protection grade IP21/23
Alternator Cooling Direct driven fan cooling
Voltage control AVR
Telephone Influence Factor <50 per NEMA MG122.43
  Available Voltage

For 50Hz

  • 220/380
  • 230/400
  • 240/415
  • 254/440

For 60Hz

  • 240/415
  • 254/440
  • 260/460
  • 277/480

Control System

PK-01 Manual Control Panel

General display

  •  GensetVoltage
  • GensetAC
  • GensetFrequency
  • Running hour counter
  • Engine oil pressure
  • Engine oil temperature
  • Coolant water temperature

Warning & shutdown protection

  • Manual Engine Control Module
  • Low Oil Pressure
  • High Engine Temperature
  • Auxiliary Shutdown
  • Overspeed Protection
  • Protection hold-off timer
  • Charge Failure warning
PFBD15 Genset Manual Control Panel

PK-02 Atomatic Control Panel  (6100 Module)

General Introduction

Model 6100 is the basic configuration for nobody on duty controlling generators. Auto start as the main power failure. Auto control system, with large LCD display in English with auto Control Panel, generator are of various functions such as auto/manual stop (emergencystop), programmable plugs for input and output, detected data, symbols, diagram will show in the LCD, etc.


Warning Functions Shutdown Functions
  • Over current
  • Start battery over voltage
  • Start battery under voltage
  • Low fuel level
  • Low water level
  • High temperature
  • Low oil pressure
  • Misplace
  • Auxiliary warning
  • Battery charger loose
  • Inhibit crank
  • Inhabit on load (login)
  • Low engine temperature
  • Switch off
  • High oil level
  • Low fuel pressure
  • Fail to synchronous
  • Low oil pressure High temperature
  • Fail to crank
  • Fail to shutdown
  • Emergency stop
  • Remote emergency stop
  • Genset voltage abnormal
  • Over voltage
  • Loss of speed signal
  • Over speed
  • Under speed
  • Over frequency
  • Underf requency
  • Battery charger loose
  • Auxiliary shutdown

 

PFBD15 15KVA Diesel Genset Auto Control Panel


LCD Display  
  • Genset Voltage (V)
  • Genset Current (Am)
  • Genset Frequency (Hz)
  • Genset Active Power (kW)
  • Genset Apparent Power (kVA)
  • Genset Power Factor
  • Genset Hour Count
  • Genset Oil Pressure
  • Genset Temperature
  • Genset Fuel Level
  • Mains Voltage (V)
  • Mains Current (Am)
  • Mains Frequency (Hz)
  • Mains Active Power  (kW)
  • Mains Apparent Power (kVA)
  • Mains Power Factor

Accessories

Standard Accessories

  • Standard control panel (Manual control)
  • Exhaust silencer with flexible pipe
  • Battery, battery cables and battery rack
  • Shock absorber
  • 6-8 hrs base fuel tank (for canopy type)
  • Dry type fuel filter, oil filter and air filter

Optional Accessories

  • Automatic control panel
  • Intelligent battery charger
  • Automatic transfer switch (ATS)
  • Paralleled control panel
  • Manual Sump Oil Drain Pump
  • Soundproof/weatherproof canopy
  • Oil-water separator
  • Water heater
  • Fuel heater
  • Trailer


Weight and Dimensions

PFDB 15 KVA Genset Dimensions

PFBD15 (Open Set)

Overall size (L x W x H mm)

1300 x 700 x 1100

PFBD15 (Canopy Set)

 Overall size (L x W x H mm)

1850 x 850 x 1450

Note: Materials and specifications are subject to change without prior notice.